Artical
No. : T06.09/T06.15/T06.25/T06.39
Standards: IEC 60335-1 / 2006-09 § 11.2 and § 11.3
Application : to measure the temperation in the bases or
in the fixing surfaces fou applicances and luminaires in operation
Standard
Outfit:
1 plywood board, 20 -2 mm thick, with frame on
all sides and with covering board at the lower side, together approx. 150 mm
thick, with 4 feet, size and layout to allow the completition to a test corner,
1 set of measuring points, consisting of: copper
disks, diameter 15 mm, 1 mm thick, embedded at distances of 50 mm x 50 mm in
the plywood board,their front flush with the surface of theplywood board,and
fine-wire thermocouples nickelchromium-nickel (NiCr-Ni), soldered tothe back of
the copper disks, thermoelectricwires with a diameter of 0,3 -0,1mm, insulated
with glass-silk or similar temperature resistant material,
1 set of change-over switches to select the
lines resp. rows of the copper disks, to connect the selected copper disk with
the socket-outlet and the temperature indicating instrument,
1 socket-outlet, two-pole, almost without
thermoelectric voltage, plug with cable of nickelchromium- nickel, length 1.5
m, for the connection of a external measuring
instrument,
1 temperature indicating instrument, supplied by
battery, and switch to select instrument or socket-outlet.
Design :
plywood board, frame and copper disks painted dull
black, copper disk lines and rows marked. Most
PTL Temperature Measuring Boards are tailormade
|